Partenaires

Logo tutelle
CNRS



Rechercher

Sur ce site

Sur le Web du CNRS


Accueil du site > Équipes > Équipe 1 : Méthodes de caractérisation et d’imagerie ultrasonore multi-echelle : modélisation et transfert > Publications, présentations et brevets > Publications

Publications

2011

1. Q. Grimal, K. Raum, A. Gerisch, P. Laugier, « A determination of the minimum sizes of representative volume elements for the prediction of cortical bone elastic properties, » Biomech Model Mechanobiol in press (2011).

2. J.-G. Minonzio, M. Talmant, P. Laugier, “Measurement of guided wave phase velocities by analysis of the transfer matrix obtained with multi-emitters and multi-receivers in contact,” J. Phys. : Conf. Ser. 269 012003 (2011).

2010

1. Anderson CC, Bauer AQ, Marutyan KR, Holland MR, Pakula M, Bretthorst GL, Laugier P, Miller JG. « Phase Velocity of Cancellous Bone : Negative Dispersion Arising from Fast and Slow Waves, Interference, Diffraction, and Phase Cancellation at Piezoelectric Receiving Elements, » In Bone Quantitative Ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

2. Anderson CC, Pakula M, Bauer AQ, Holland MR, Laugier P, Bretthorst GL, Miller JG. « Inverse problems in cancellous bone : Estimation of the ultrasonic properties of fast and slow waves using Bayesian probability theory, » J. Acoust. Soc. Am.128, 2940-2948 (2010).

3. Barkmann R, Dencks S, Laugier P, Padilla F, Brixen K, Ryg J, Seekamp A, Mahlke L, Bremer A, Heller M, Glüer CC. « Femur Ultrasound (FemUS) – first clinical results on hip fracture discrimination and estimation of femoral BMD, » Osteoporos Int 21:969-976 (2010).

4. Bosisio MR, Hasquenoph JM, Yon S, Sandrin L, Laugier P, Bridal L. « A Programmable, broadband UBM system for imaging research : Example implementation and evaluation of real-time chirp coded-imaging, » IEEE Trans Biomed Eng 57:654-664 (2010).

5. Bossy E, Grimal Q. « Numerical Methods for Ultrasonic Bone Characterization, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

6. Bréban S, Padilla F, Fujisawa Y, Mano I, Benhamou CL, Otani T, Laugier P, Chappard C. « Trabecular and cortical bone separately assessed at radius with a new ultrasound device, in a young adult population with various physical activities, » Bone 46:1620-1625 (2010).

7. Grondin J, Grimal Q, Engelke K, Laugier P. « Potential of QUS to assess cortical bone geometry at the hip : a model based study, » Ultrasound Med Biol. 36, 656-666 (2010).

8. Laugier P. « Quantitative Ultrasound Instrumentation for Bone In Vivo Characterization, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

9. Laugier P, Haïat G. « Introduction, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

10. Laugier P, Haïat G. « Introduction to the Physics of Ultrasound, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

11. Le Guillou-Buffello D, Chesneau C, Gindre M, Hélary G, Laugier P, Migonney V. « Inhibition of angiogenesis in vitro with solubles copolymers monitored with a quartz crystal resonator, » IRBM, Ingénierie et Recherche Biomédicale 2010 ;

12. Longo R, Grimal Q, Laugier P, Vanlanduit S, Guillaume P. « Simultaneous determination of acoustic velocity and density of a bone slab : Ultrasonic model-based approach, » IEEE Trans Ultrason Ferroelec Freq Contr 57,496-500 (2010).

13. Mamou J, Coron A, Hata M, Machi J, Yanagihara E, Laugier P, Feleppa EJ. « Three-dimensional High-Frequency Characterization of Cancerous Lymph Nodes, » Ultrasound Med Biol 36, 361-375 (2010).

14. Minonzio JG, Talmant M, Laugier P. « Guided waves analysis using multi-emitters and multi-receivers arrays : decomposition of the transmission matrix, » J Acoust Soc Am 127, 2913-2919 (2010).

15. Mitton D, Roux C, Laugier P. « Bone Overview, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

16. Muller M, Renaud G. « Nonlinear Acoustics for Non-invasive Assessment of Bone Micro-damage, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

17. Naili S, Vu MB, Grimal Q, Talmant M, Desceliers C, Soize C, Haiat G. « Influence of viscoelastic and viscous absorption on ultrasonic wave propagation in cortical bone : Application to axial transmission, » J Acoust Soc Am 127, 2622-2634 (2010).

18. Padilla F, Wear KA. « Scattering by Trabecular Bone, » In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

19. M. Talmant, M. Defontaine, D. Certon, G. Férin, R. Dufait, J.-G. Minonzio, T.-L. Pham, and P. Laugier, « Dispositif pour la détermination de facteurs de qualité osseuse (épaisseurs corticales, vitesses) par ultrasons : approche multimodale et multifréquence : le projet ANR-TecSan EVA, » IRBM 31, 92-96 (2010), Numéro Spécial ANR.

20. M. Talmant, J. Foiret, and J.-G. Minonzio, “Guided waves in cortical bones,"In Bone Quantitative ultrasound, P. Laugier & G. Haïat Eds. New York : Springer, 2010.

21. J. Rivière, G. Renaud, S. Haupert, M. Talmant, P. Laugier, and P. A. Johnson, “Nonlinear acoustic resonances to probe a threaded interface,” Journal of Applied Physics PPLIED 107, 124901 (2010).

22. C. B. Machado, W. C. D. Pereira, M. Talmant, F. Padilla, and P. Laugier, « Computational Evaluation of the Compositional Factors in Fracture Healing Affecting Ultrasound Axial Transmission Measurements, » Ultrasound in Medicine and Biology 36(8), 1314-1326 (2010).

2009

1. L. Vastel, C. Masse, E. Crozier, P. Mesnil, F. Padilla, P. Laugier, D. Mitton, R. Bardonnet, and J.-P. Courpied, « Comparative ultrasound evaluation of human trabecular bone graft properties after treatment with different sterilisation procedures, » J Biomed Mat Res part B (2009).

2. M. Talmant, S. Kolta, C. Roux, D. Haguenauer, I. Vedel, B. Cassou, E. Bossy, and P. Laugier, « In vivo performance evaluation of bi-directional ultrasonic axial transmission for cortical bone assessment, » Ultrasound Med Biol 35(6), 912-919 (2009).

3. W. J. Parnell and Q. Grimal, « The influence of mesoscale porosity on cortical bone anisotropy. Investigations via asymptotic homogenization, » J R Soc Interface 6(30), 97-109 (2009).

4. K. Mizuno, M. Matsukawa, T. Otani, P. Laugier, and F. Padilla, « Propagation of two longitudinal waves in human cancellous bone : an in vitro study, » J Acoust Soc Am. 125(5), 3460-3466 (2009).

5. G. Haïat, S. Naili , Q. Grimal, M. Talmant, C. Desceliers, and C. Soize, « Influence of a gradient of material properties on ultrasonic wave propagation in cortical bone : application to axial transmission, » J Acoust Soc Am 125(6), 4043-4052 (2009).

6. C. Desceliers, C. Soize, Q. Grimal, M. Talmant, and S. Naili, « Determination of the random anisotropic elasticity layer using transient wave propagation in a fluid-solid multilayer : model and experiments, » J Acoust Soc Am 125(4), 2027-2034 (2009).

7. G. Haïat, F. Padilla, M. Svrcekova, Y. Chevalier, D. Pahr, F. Peyrin, P. Laugier, P. Zysset, « Relationship between ultrasonic parameters and apparent trabecular bone elastic modulus : A numerical approach, » J Biomech 2009 ;42:2033-9.

8. R. Barkmann, S. Dencks, P. Laugier, F. Padilla, K. Brixen, J. Ryg, A. Seekamp, L. Mahlke, A. Bremer, M. Heller, C. C. Glüer, « Femur ultrasound (FemUS) : a first clinical results on hip fracture discrimination and estimation of femoral BMD, » Osteoporos Int. Available Online, DOI 10.1007/s00198-009-1037-4, 2009.

9. M. Pakula, F. Padilla and P. Laugier. « Influence of the filling fluid on frequency-dependent velocity and attenuation in cancellous bones between 0.35 and 2.5 MHz, » J Acoust Soc Am. 126, 3301-3310 (2009).

10. Grimal, Q., S. Haupert, D. Mitton, L. Vastel, and P. Laugier, « Assessment of cortical bone elasticity and strength : mechanical testing and ultrasound provide complementary data, » Med Eng Phys, 2009. 31(9) : p. 1140-7.

11. Sasso M, Talmant M, Haiat G, Naili S, Laugier P. Analysis of the most energetic low frequency arrival in axially transmitted signals in cortical bone. IEEE Trans Ultrason Ferroelec Freq Contr 2009 ;56:2463-70.

12. Rupin F, Saïed A, Dalmas D, Peyrin F, Haupert S, Raum K, Barthel E, Boivin G, Laugier P. « Assessment of Microelastic Properties of Bone Using Scanning Acoustic Microscopy : a Face-to-Face Comparison with Nanoindentation, » Japenese J Applied Phys 2009 ;48:07GK1/1-6.

13. Mamou J, Coron A, Hata M, Machi J, Yanagihara E, Laugier P, Feleppa EJ.« High-Frequency Quantitative Ultrasound Imaging of Cancerous Lymph Nodes, » Japenese J Applied Phys 2009 ;48:07GK8/1-8.

14. Amichi A, Laugier P. Quantitative texture analysis and transesophageal echocardiography to characterize the acute myocardial contusion. Open Med Inform J 2009 ;13-8.

2008

1. K. Wear, F. Padilla, and L. P., « Comparison of the Faran Cylinder Model and the Weak Scattering Model for predicting of frequency dependence of backscatter from human cancellous femur in vitro, » J Acoust Soc Am 124.(3), 1408-1410 (2008).

2. M. Sasso, G. Haiat, M. Talmant, P. Laugier, and S. Naili « SVD-based algorithm for axial transmission ultrasound technique application to cortical bone characterization, » IEEE Trans Ultrason Ferroelectr Freq Contr 55(1328-1332 ), 1328-1332 (2008).

3. A. Saïed, K. Raum, I. Leguerney, and P. Laugier, « Spatial distribution of acoustic impedance assessed by scanning acoustic microscopy (50 MHz) and its relation to porosity in human cortical bone, » Bone 43(1), 187-194 (2008).

4. W. J. Parnell and Q. Grimal, « The influence of mesoscale porosity on cortical bone anisotropy. Investigations via asymptotic homogenization, » J R Soc Interface (2008).

5. M. Pakula, F. Padilla, M. Kaczmarek, and P. Laugier, « Application of Biot’s theory to ultrasonic characterization of human cancellous bones. Part 1. Determination of structural, material and mechanical properties, » J Acoust Soc Am 123(4), 2415-2423 (2008).

6. F. Padilla, F. Jenson, V. Bousson, F. Peyrin, and P. Laugier, « Relationships of Trabecular bone structure with quantitative ultrasound parameters : in vitro study on human proximal femur using trasnmission and backscatter measurements, » Bone 42(6), 1193-1202 (2008).

7. F. Padilla, Q. Grimal, and P. Laugier, « Ultrasonic Propagation Through Trabecular Bone Modeled As A Random Medium, » Japanese Journal of Applied Physics 47(5B)(2008).

8. M. Muller, T. J. Ulrich, M. Talmant, D. Mitton, P. Laugier, and P. Johnson, Application of nonlinear elastic wave spectroscopy (NEWS) to in vitro damage assessment in cortical bone, In Biomedical applications of vibration and acoustics for imaging, characterization and diagnostics (ASME Press, 2008).

9. M. Muller, D. Mitton, M. Talmant, P. A. Johnson, and P. Laugier, « Nonlinear ultrasound can detect accumulated damage in human bone, » J Biomech 41(5), 1062-1068 (2008).

10. M. Muller, D. Mitton, P. Moilanen, V. Bousson, M. Talmant, and P. Laugier, « Prediction of bone mechanical properties using QUS and p-QCT : study of the human distal radius, » Med Eng Physics 30(6), 761-767 (2008).

11. P. Moilanen, M. Talmant, V. Kilappa, P. Nicholson, S. Cheng, J. Timonen, and P. Laugier, « Modeling the impact of soft tissue on axial transmission measurements of ultrasonic guided waves in long bones, » J Acoust Soc Am 124(4), 2364-2373 (2008).

12. D. Le Guillou-Buffello, R. Bareille, M. Gindre, A. Sewing, P. Laugier, and J. Amédée-Vilamitjana, « Additive Effect of RGD Coating to Functionalized Titanium Surfaces on Human OsteoProgenitor Cell Adhesion and Spreading, » Tissue Eng Part A 14(8), 1445-1455 (2008).

13. P. Laugier, T.-L. Pham, and M. Talmant, « Quo vadis, ultrasonics of bone ? Present state and future trends, » Archives of Acoustics 33, 413-424 (2008).

14. P. Laugier, C. Baron, and M. Talmant, « Quantitative ultrasound for cortical bone characterization, » Osteoporos Int 19(6), 863-867 (2008).

15. P. Laugier, W. K. A., and K. R. Waters, « Introduction to the special issue on diagnostic and therapeutic applications of ultrasound in bone, » IEEE Trans Ultrason Ferroelec Freq Contr 55(6), 1177-1178 (2008).

16. P. Laugier, « Instrumentation for in vivo assessment of bone strength, » IEEE Trans Ultrason Ferroelec Freq Contr 55(6), 1179-1196 (2008).

17. G. Haïat, F. Padilla, and P. Laugier, « Sensitivity of QUS parameters to controlled variations of bone strength assessed with a cellular model, » IEEE Trans Ultrason Ferroelec Freq Contr 19(7), 1488-1496 (2008).

18. G. Haïat, F. Padilla, and P. Laugier, « Fast wave propagation in trabecular bone : numerical study of the influence of porosity and structural anisotropy, » J Acoust Soc Am 123(3), 1694-1705 (2008).

19. G. Haïat, A. Lhémery, F. Renaud, F. Padilla, P. Laugier, and S. Naili, « Frequency dependence of phase velocity in trabecular bone : influence of multiple scattering and of absorption, » J Acoust Soc Am 124( 6), 4047-4058 (2008).

20. Q. Grimal, K. Raum, A. Gerisch, and P. Laugier, « Derivation of the mesoscopic elasticity tensor of cortical bone from quantitative impedance images at the micron scale, » Comput Methods Biomech Biomed Engin 11(2), 147-157 (2008).

21. S. Dencks, R. Barkmann, F. Padilla, P. Laugier, G. Schmitz, and C.-C. Glüer, « Model-based estimation of Quantitative Ultrasound variables at the proximal femur, » IEEE Trans Ultrason Ferroelec Freq Contr 55(8), 1304-1315 (2008).

22. R. Barkmann, P. Laugier, U. Moser, S. Dencks, M. Klausner, F. Padilla, G. Haiat, M. Heller, and C.-C. Glüer, « A Device for In vivo Measurements of Quantitative Ultrasound Variables at the Human Proximal Femur, » IEEE Trans Ultrason Ferroelec Freq Contr 55(6), 1197-1204 (2008).

23. R. Barkmann, P. Laugier, U. Moser, S. Dencks, M. Klausner, F. Padilla, G. Haiat, M. Heller, and C.-C. Glüer, « In vivo measurments of ultrasound transmission through the human proximal femur, » Ultrasound Med Biol 34(7), 1186-1190 (2008).

24. A. Aubry, A. Derode, and F. Padilla, « Local measurements of the diffusion constant in multiple scattering media : Application to human trabecular bone imaging, » Applied Physics Letter 124101, 92 (2008).

2007

1. L. Vastel, C. Masse, E. Crozier, F. Padilla, P. Laugier, D. Mitton, R. Bardonnet, and J. P. Courpied, « Effects of gamma irradiation on mechanical properties of defatted trabecular bone allografts assessed by speed-of-sound measurement, » Cell Tissue Bank 8(3), 205-210 (2007).

2. T. J. Ulrich, P. A. Johnson, M. Müller, D. Mitton, M. Talmant, and P. Laugier, « Application of Nonlinear Dynamics to Monitoring Progressive Fatigue Damage in Human Bone, » Applied Phys Letter 91, 213901 (2007).

3. K. Raum, T. Hofman, I. Leguerney, A. Saïed, F. Peyrin, L. Vico, and P. Laugier, « Variations of microstructure, mineral density and tissue elasticity in B6/C3H mice, » Bone 41(6), 1017-1024 (2007).

4. P. Moilanen, M. Talmant, P. H. F. Nicholson, S. Cheng, J. Timonen, and P. Laugier, « Ultrasonically determined thickness of long cortical bones : three-dimensional simulations of in vitro experiments, » J Acoust Soc Am 122(4), 2439-2445 (2007).

5. P. Moilanen, M. Talmant, V. Bousson, P. H. F. Nicholson, S. Cheng, J. Timonen, and P. Laugier, « Ultrasonically determined thickness of long cortical bones : two-dimensional simulations of in vitro experiments, » J Acoust Soc Am 122(3), 1818-1826 (2007).

6. P. Laugier, G. Haiat, and F. Padilla, « Computer simulations of ultrasonic propagation in trabecular bone, » Computers Biol Med 37(12), 1827-1828 (2007).

7. G. Haiat, F. Padilla, F. Peyrin, and P. Laugier, « Variation of Ultrasonic Parameters with Microstructure and Material Properties of Trabecular Bone : a Three-Dimensional Model Simulation, » J Bone Miner Res 22(5), 665-674 (2007).

8. S. Dencks, R. Barkmann, P. Laugier, G. Haïat, F. Padilla, and C.-C. Glüer, « Introduction of a wavelet-based method for more robust Quantitative Ultrasound (QUS) signal processing to estimate bone mineral density at the proximal femur, » Ultrasound Med Biol 33(6), 970-980 (2007).

9. M. Boudinet, O. Bergès, L. Lumbroso, L. Desjardins, and P. Laugier, « Quantitative echography in the follow-up of patients treated with proton beam irradiation for primary choroidal melanomas, » Ultrasound Med biol 33(7), 1046-1056 (2007).

10. E. Bossy, P. Laugier, and F. Padilla, « Attenuation in trabecular bone : a face-to-face comparison between numerical simulation and experimental results, » J Acoust Soc Am 122(4), 2469-2475 (2007).

11. C. Baron, M. Talmant, and P. Laugier, « Effect of porosity on effective stiffness (c11, c 22, c33, c44, c55 and c66) and elastic anisotropy of cortical bone at 1 MHz : a finite-difference time domain study, » J Acoust Soc Am 122(3), 1810-1817 (2007).

12. R. Barkmann, P. Laugier, U. Moser, S. Dencks, F. Padilla, G. Haiat, M. Heller, and C. C. Gluer, « A method for the estimation of femoral bone mineral density from variables of ultrasound transmission through the human femur, » Bone (1), 37-44 (2007).

2006

1. K. Raum, I. Leguerney, F. Chandelier, M. Talmant, A. Saïed, F. Peyrin, and P. Laugier, « Site-matched assessment of structural and tissue properties of cortical bone using scanning acoustic microscopy and synchrotron radiation μCT, » Phys Med Biol 51, 733-746 (2006).

2. K. Raum, R. O. Cleveland, F. Peyrin, and P. Laugier, « Derivation of elastic stiffness from site-matched mineral density and acoustic impedance maps, » Phys Med Biol 51, 747-758 (2006).

3. F. Padilla, F. Jenson, and P. Laugier, « Influence of the precision of spectral backscatter measurements on the estimation of scatterers size in cancellous bone, » Ultrasonics. 44S, e57-e60 (2006).

4. F. Padilla, F. Jenson, and P. Laugier, « Estimation of trabecular thickness using ultrasound ultrasonic baclkscatter, » Ultrasonic Imaging 28, 3-22 (2006).

5. F. Padilla, E. Bossy, and P. Laugier, « Simulation of ultrasound propagation through three-dimensional trabecular bone structures : comparison with experimental data, » Japanese J Applied Phys 45(8A), 6496-6500 (2006).

6. F. Padilla, E. Bossy, G. Haiat, F. Jenson, and P. Laugier, « Numerical simulation of wave propagation in cancellous bone, » Ultrasonics. 44S, e239-e243. (2006).

7. M. Muller, J. A. Tencate, T. W. Darling, A. Sutin, R. A. Guyer, M. Talmant, P. Laugier, and P. A. Johnson, « Bone micro-damage assessment using non-linear resonant ultrasound spectroscopy (NRUS) techniques : A feasibility study, » Ultrasonics. 44S, e245-e249 (2006).

8. M. Meziri, « Approche multiparamétrique de la caractérisation de la fibrose hépatique par ultrasons 20 MHz, » (Université d’Annaba, Annaba, 2006).

9. K. Macocco, Q. Grimal, S. Naili, and C. Soize, « Elastoacoustic model with uncertain mechanical properties for ultrasonic wave velocity prediction : application to cortical bone evaluation., » J Acoust Soc Am 119 729-740 (2006).

10. C. B. Machado, W. C. A. Pereira, M. Meziri, and P. Laugier, « Caracterização da Periodicidade de Tecido Hepático Humano Saudável in Vitro Usando Sinais de Ultra-Som, » Brazilian Journal of Biomedical Engineering 22(3), 131-139 (2006).

11. C. B. Machado, W. C. Pereira, M. Meziri, and P. Laugier, « Characterization of in vitro healthy and pathological human liver tissue periodicity using backscattered ultrasound signals, » Ultrasound Med Biol. 32(5), 649-657. (2006).

12. P. Laugier, « Quantitative ultrasound of bone : looking ahead, » Joint Bone Spine. 73(2), 125-128 (2006).

13. P. Laugier, Challenges in quantitative ultrasound bone strength assessment : status and perspectives., Computerized Tomography for Scientists and Engineers (Anamaya Publishers, New Delhi, India, 2006), pp. 57-67.

14. P. Lasaygues and P. Laugier, Bone Imaging Using Compound Ultrasonic Tomography, Computerized Tomography for Scientists and Engineers (Anamaya Publishers, New Delhi, India, 2006), pp. 48-56.

15. E. Jouannot, J. P. Duong-Van-Huyen, K. Bourahla, P. Laugier, M. Lelievre-Pegorier, and L. Bridal, « High-frequency ultrasound detection and follow-up of Wilms’ tumor in the mouse, » Ultrasound Med Biol 32(2), 183-190 (2006).

16. F. Jenson, F. Padilla, V. Bousson, C. Bergot, J. D. Laredo, and P. Laugier, « In vitro ultrasonic characterization of human cancellous femoral bone using transmission and backscatter measurements : relationships to bone mineral density, » J Acoust Soc Am 119, 654–663 (2006).

17. T. Hofman, K. Raum, I. Leguerney, A. Sai Ed, F. Peyrin, L. Vico, and P. Laugier, « Assessment of bone structure and acoustic impedance in C3H and BL6 mice using high resolution scanning acoustic microscopy, » Ultrasonics. 44S, e1307-e1311.. (2006).

18. G. Haiat, F. Padilla, R. Cleveland, and P. Laugier, « Effects of frequency dependent attenuation and velocity dispersion on in vitro ultrasound velocity measurements in intact human femur specimens, » IEEE Trans Ultrason Ferroelec Freq Contr 53(1), 39-52 (2006).

19. G. Haiat, F. Padilla, R. Barkmann, C. C. Gluer, and P. Laugier, « Numerical simulation of the dependence of quantitative ultrasonic parameters on trabecular bone microarchitecture and elastic constants, » Ultrasonics. 44S, e289-e294. Epub 2006 Jun 2030. (2006).

20. Q. Grimal and S. Naili, « Theoretical analysis in the time-domain of wave reflection on bone plate. , » J Sound Vibration 298(1-2), 12-29 (2006).

21. C. Chappard, C. Roux, P. Laugier, P. Paillard, and P. Houillier, « Statut osseux au cours de l’hyperparathyroïdie primitive mesurée par densité minérale osseuse régionale par densitométrie corps entier et ultrasonographie quantitative au calcanéum, » Revue du Rhumatisme 73(1), 83-92 (2006).

22. C. Chappard, C. Roux, P. Laugier, M. Paillard, and P. Houillier, « Bone status in primary hyperparathyroidism assessed by regional bone mineral density from the whole body scan and QUS imaging at calcaneus, » Joint Bone Spine 73 (1), 86-94 (2006).

23. S. L. Bridal, C. Fournier, A. Coron, I. Leguerney, and P. Laugier, « Ultrasonic backscatter and attenuation (11-27 MHz) variation with collagen fiber distribution in ex vivo human dermis, » Ultrason Imaging 28(1), 23-40 (2006).

24. M. R. Bosisio, M. Talmant, W. Skalli, P. Laugier, and D. Mitton, « Apparent Young’s modulus of human radius using inverse finite-element method, » J Biomech 40(9), 2022-2028 (2006).

25. I. Al Haffar, F. Padilla, R. Nefussi, S. Kolta, J. M. Foucart, and P. Laugier, « Experimental evaluation of bone quality measuring speed of sound in cadaver mandibles, » Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 102(6), 782-791. Epub 2006 Jul 2027. (2006).

2005

1. K. Raum, I. Leguerney, F. Chandelier, E. Bossy, M. Talmant, A. Saïed, F. Peyrin, and P. Laugier, « Structural and elastic determinants of axial transmission ultrasonic velocity in the human radius, » Ultrasound Med Biol 31(9), 1225-1235 (2005).

2. F. Padilla and P. Laugier, « Recent developments in trabecular bone characterization using ultrasound, » Current Osteoporosis Reports 3(2), 64-69 (2005).

3. M. Muller, P. Moilanen, E. Bossy, P. Nicholson, V. Kilappa, J. Timonen, M. Talmant, S. Cheng, and P. Laugier, « Comparison of three ultrasonic axial transmission methods for bone assessment, » Ultrasound Med Biol 31(5), 633-642. (2005).

4. M. Muller, R. Guyer, P. Laugier, and P. A. Johnson, « Nonlinear resonant ultrasound spectroscopy applied to damage assessment in bone, » J Acoust Soc Am 118 (6), 3946-3952 (2005).

5. M. Meziri, W. C. Pereira, A. Abdelwahab, C. Degott, and P. Laugier, « In vitro chronic hepatic disease characterization with a multiparametric ultrasonic approach, » Ultrasonics 43(5), 305-313. (2005).

6. K. Macocco, Q. Grimal, S. Naili, and C. Soize, « Modélisation probabiliste d’une expérience ultrasonore : calcul de la dispersion sur les mesures de célérité, » Comptes Rendus Mécanique 333(7), 565-573 (2005).

7. D. Le Guillou-Buffello, G. Helary, M. Gindre, G. Pavon-Djavid, P. Laugier, and V. Migonney, « Monitoring cell adhesion processes on bioactive polymers with the quartz crystal resonator technique, » Biomaterials 26(19), 4197-4205. (2005).

8. P. Laugier, F. Padilla, F. Peyrin, K. Raum, A. Saied, M. Talmant, and L. Vico, « Current trends in the ultrasonic investigation of bone, » ITBM-RBM 26(5-6), 299-311 (2005).

9. P. Laugier, « Ultrasonographie quantitative osseuse : quelles perspectives pour l’avenir ?, » Revue du Rhumatisme 73(3), 207-209 (2005).

10. P. Laugier, « Apport des ultrasons dans l’exploration du tissu osseux, » in La fragilité osseuse et ses déterminants. Réunion d’interface INSERM Appareil Locomoteur., C. L. Benhamou, ed. (INSERM, Paris, 2005), pp. 43-54.

11. P. Lasaygues, E. Ouedraogo, J. P. Lefebvre, M. Gindre, M. Talmant, and P. Laugier, « Progress towards in vitro quantitative imaging of human femur using compound quantitative ultrasonic tomography, » Phys Med Biol 50(11), 2633-2649. Epub 2005 May 2618. (2005).

12. C. Jolly, J. C. Jeanny, F. Behar-Cohen, P. Laugier, and A. Saied, « High-resolution ultrasonography of subretinal structure and assessment of retina degeneration in rat, » Exp Eye Res 81(5), 592-601. Epub 2005 Jun 2009. (2005).

13. D. Hans, I. Alekxandrova, C. Njeh, C. Le-Floch, G. Conicella, P. Laugier, and D. O. Slosman, « Appropriateness of internal digital phantoms for monitoring the stability of the UBIS 5000 quantitative ultrasound device in clinical trials, » Osteoporos Int 16, 435-445 (2005).

14. G. Haiat, F. Padilla, R. Barkmann, S. Kolta, C. Latremouille, C. C. Gluer, and P. Laugier, « In vitro speed of sound measurement at intact human femur specimens, » Ultrasound Med Biol 31(7), 987-996. (2005).

15. G. Haiat, F. Padilla, R. Barkmann, S. Dencks, U. Moser, C. C. Gluer, and P. Laugier, « Optimal Prediction of Bone Mineral Density with Ultrasonic Measurements in Excised Human Femur, » Calcif Tissue Int 15(3), 186-192 (2005).

16. Q. Grimal, S. Naili, and A. Watzky, « A high-frequency lung injury mechanism in blunt thoracic impact., » J Biomech 38, 1247-1254 (2005).

17. Q. Grimal and S. Naïli, « Injury mechanism in blunt thoracic non-penetrating impact : finite element study, » Revue européenne des éléments finis 14 (4-5), 517-540 (2005).

18. A. Derode, V. Mamou, F. Padilla, F. Jenson, and P. Laugier, « Dynamic coherent backscattering in a heterogeneous absorbing medium : application to human trabecular bone characterisation, » Applied Physics Letter 87, 114101-114101- 114101-114103 (2005).

19. E. Bossy, F. Padilla, F. Peyrin, and P. Laugier, « Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography, » Phys Med Biol 50, 5545-5556 (2005).

2004

1. Y. P. Zheng, S. L. Bridal, J. Shi, A. Saied, M. H. Lu, B. Jaffre, A. F. Mak, and P. Laugier, « High resolution ultrasound elastomicroscopy imaging of soft tissues : system development and feasibility, » Phys Med Biol 49(17), 3925-3938. (2004).

2. A. Saied and P. Laugier, « High resolution ultrasonography for analysis of age- and disease-related cartilage changes, » in In Cartilage and Osteoarthritis : Structure and In Vivo Analysis, F. De Ceuninck, P. Pastoureau, and M. Sabatini, eds. (Humana Press, Totowa, NJ, USA, 2004), pp. 251-267.

3. A. Saied and P. Laugier, « High-resolution ultrasonography for analysis of age- and disease-related cartilage changes, » Methods Mol Med 101, 249-266. (2004).

4. W. C. Pereira, S. L. Bridal, A. Coron, and P. Laugier, « Singular spectrum analysis applied to backscattered ultrasound signals from in vitro human cancellous bone specimens, » IEEE Trans Ultrason Ferroelectr Freq Control 51(3), 302-312. (2004).

5. F. Padilla, L. Akrout, S. Kolta, C. Latremouille, C. Roux, and P. Laugier, « In vitro ultrasound measurement at the human femur, » Calcif Tissue Int 75(5), 421-430. Epub 2004 Jun 2017. (2004).

6. D. Le Guillou-Buffello, G. Helary, M. Gindre, G. Pavon-Djavid, P. Laugier, and V. Migonney, « Mesure de l’inhibition de l’adhésion cellulaire sur cinq films de polymère par la technique du résonateur à quartz., » ITBM-RBM 25, 34-39 (2004).

7. P. Laugier, F. Lefebvre, C. Chappard, and C. Roux, « Segmentation of quantitative ultrasonographic images of the calcaneus using elastic deformation of the flexible Fourier contour, » J Ultrasound Med 23(5), 693-699. (2004).

8. P. Laugier, E. Bossy, F. Jenson, F. Padilla, M. Talmant, and In . Eds. , , pp. , . « Évaluation la Résistance Osseuse in Vivo par ultrasons, » in Imagerie et photonique pour les sciences du vivant et la médecine, P. S. M. Faupel, R Grzymala, ed. (FontisMedia SA, Lausanne, Switzerland, 2004), pp. 127-142.

9. L. Haider, M. Gindre, D. Leguillou-Buffelo, P. Laugier, H. Perrot, F. Carreiras, and H. Darbeida, « Cell attachment and spreading processes monitored by the thickness shear mode quartz sensor, » IEEE Sensors J 4(5), 535-542 (2004).

10. C.-C. Glüer, R. Barkmann, F. Padilla, and P. Laugier, « Apparatus for the positioning of ultrasonic transducers for the determination of bone properties, » (2004).

11. C. C. Glüer, R. Barkmann, F. Padilla, and P. Laugier, « Apparatus for the determination of bone density using ultrasound, » (2004).

12. M. Defontaine, S. Bonneau, F. Padilla, M. A. Gomez, M. Nasser Eddin, P. Laugier, and F. Patat, « 2D arrays device for calcaneus bone transmission : an alternative technological solution using crossed beam forming, » Ultrasonics 42(1-9), 745-752. (2004).

13. S. L. Bridal, E. Jouannot, C. Jolly, A. Saied, J.-M. Correas, and P. Laugier, « Ultrasonographie de haute fréquence du petit animal, » in Imagerie et photonique pour les sciences du vivant et la médecine, M. Faupel, P. Smigielski, and R. Grzymala, eds. (FontisMedia SA, Lausanne Switzerland, 2004), pp. 257-273.

14. E. Bossy, M. Talmant, F. Peyrin, L. Akrout, P. Cloetens, and P. Laugier, « An in vitro study of the ultrasonic axial transmission technique at the radius : 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity, » J Bone Miner Res 19(9), 1548-1556. Epub 2004 Jun 1502. (2004).

15. E. Bossy, M. Talmant, and P. Laugier, « Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models, » J Acoust Soc Am 115(5 Pt 1), 2314-2324. (2004).

16. E. Bossy, M. Talmant, M. Defontaine, F. Patat, and P. Laugier, « Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone : a validation on test materials, » IEEE Trans Ultrason Ferroelectr Freq Control 51(1), 71-79. (2004).

2003

1. K. R. Waters, S. L. Bridal, C. Cohen-Bacrie, C. Levrier, P. Fornes, and P. Laugier, « Parametric analysis of carotid plaque using a clinical ultrasound imaging system, » Ultrasound Med Biol 29(11), 1521-1530. (2003).

2. F. Padilla, F. Peyrin, and P. Laugier, « Prediction of backscatter coefficient in trabecular bones using a numerical model of three-dimensional microstructure, » J Acoust Soc Am 113(2), 1122-1129. (2003).

3. P. Laugier, M. Tanter, E. Bossy, and J.-F. Aubry, « Ultrasons : de la physique fondamentale à la médecine, » in La physique pour la santé : du diagnostic à la thérapie. Actes de e2phy 2002, Ecole d’été de Physique, Lyon, 26-29 août 2002, M. K. e. J.-C. Poizat, ed. (2003), pp. 133-147.

4. F. Jenson, F. Padilla, and P. Laugier, « Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model, » Ultrasound Med Biol 29(3), 455-464. (2003).

5. B. Jaffre, A. Watrin, D. Loeuille, P. Gillet, P. Netter, P. Laugier, and A. Saied, « Effects of antiinflammatory drugs on arthritic cartilage : a high-frequency quantitative ultrasound study in rats, » Arthritis Rheum 48(6), 1594-1601. (2003).

6. C. Haddad, F. Prat, F. Lefebvre, A. Amichi, P. Laugier, S. Zidi, G. Pelletier, J. Fritsch, G. Berger, and C. Buffet, (1), , . « Caractérisation des ganglions lymphatiques péridigestifs par échoendoscopie : intérêt de l’imagerie paramétrique et analyse quantitative, » Acta endoscopica 33(1), 127 - 137 (2003).

7. C. Fournier, S. L. Bridal, A. Coron, and P. Laugier, « Optimization of attenuation estimation in reflection for in vivo human dermis characterization at 20 MHz, » IEEE Trans Ultrason Ferroelectr Freq Control 50(4), 408-418. (2003).

8. L. Bridal, J.-M. Correas, A. Saïed, and P. Laugier, « Milestones on the road to higher resolution, quantitative and functional ultrasonic imaging., » Proceedings of the IEEE Special Issue on Emerging Medical Technology 91(10), 1543-1561 (2003).

2002

1. M. Talmant, E. Bossy, and P. Laugier, « Procédé, sonde et appareil pour caractériser par voie ultrasonore un milieu d’étude, en particulier la couche cortical d’un os, » (2002).

2. M. Talmant, E. Bossy, and P. Laugier, « Procédé, sonde et appareil pour évaluer de manière non-invasive une durée de parcours ou une vitesse d’ultrasons le long d’une interface, notamment osseuse, » (2002).

3. A. Saïed, A. Petetin, P. Laugier, G. Berger, J. Oliviera Sousa, and B. Audenard, « Système de balayage selon un trajet arciforme à rayon de courbure variable, » (2002).

4. B. Pellaumail, A. Watrin, D. Loeuille, P. Netter, G. Berger, P. Laugier, and A. Saied, « Effect of articular cartilage proteoglycan depletion on high frequency ultrasound backscatter, » Osteoarthritis Cartilage 10(7), 535-541. (2002).

5. E. Ouedraogo, P. Lasaygues, J. P. Lefebvre, M. Gindre, M. Talmant, and P. Laugier, « Contrast and velocity ultrasonic tomography of long bones, » Ultrason Imaging 24(3), 139-160. (2002).

6. P. Laugier, A. Saïed, A. Petetin, and J. Abascal, « Dispositif d’interface pour l’échographie oculaire sans contamination des sondes, » (2002).

7. M. A. Gomez, M. Defontaine, B. Giraudeau, E. Camus, L. Colin, P. Laugier, and F. Patat, « In vivo performance of a matrix-based quantitative ultrasound imaging device dedicated to calcaneus investigation, » Ultrasound Med Biol 28(10), 1285-1293. (2002).

8. P. Cozzone, F. Pain, R. Mastrippolito, P. Laniece, P. Laugier, L. Bridal, A. Saïed, and S. Charpak, « L’imagerie du petit animal, » Biofutur 220, 44-48 (2002).

9. S. Chaffai, F. Peyrin, S. Nuzzo, R. Porcher, G. Berger, and P. Laugier, « Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements : relationships to density and microstructure, » Bone 30(1), 229-237. (2002).

10. E. Bossy, M. Talmant, and P. Laugier, « Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission : a 2D simulation study, » J Acoust Soc Am 112(1), 297-307. (2002).

2001

1. C. Roux, V. Roberjot, R. Porcher, S. Kolta, M. Dougados, and P. Laugier, « Ultrasonic backscatter and transmission parameters at the os calcis in postmenopausal osteoporosis, » J Bone Miner Res 16(7), 1353-1362. (2001).

2. F. Padilla, M. Gindre, and J. Y. Le Huerou, « Model and measurements of the electrical input impedance of a plate-liquid-plate acoustic resonator, » IEEE Trans Ultrason Ferroelectr Freq Control 48(3), 838-843. (2001).

3. P. Laugier, « Bases physiques de l’échographie, » in Échographie, 2e édition ed., A. Bonnin, P. Legmann, J.-P. Convard, and C. Broussouloux, eds. (Masson, Paris, 2001), pp. 1-27.

4. C. Fournier, S. L. Bridal, G. Berger, and P. Laugier, « Reproducibility of skin characterization with backscattered spectra (12—25 MHz) in healthy subjects, » Ultrasound Med Biol 27(5), 603-610. (2001).

5. E. Cherin, A. Saied, B. Pellaumail, D. Loeuille, P. Laugier, P. Gillet, P. Netter, and G. Berger, « Assessment of rat articular cartilage maturation using 50-MHz quantitative ultrasonography, » Osteoarthritis Cartilage 9(2), 178-186. (2001).

2000

1. C. Roux, D. Hans, M. A. Krieg, and P. Laugier, « Usage des ultrasons dans l’évaluation de l’ostéoporose post-ménopausique, » Médecine et Hygiène 58, 2305 (2000).

2. F. Padilla, B. Poirée, G. Quentin, and M. Talmant, « The wave bivector formalism associated to the circumferential leaky waves, » J Acoust Soc Am 108, 25-30 (2000).

3. F. Padilla and P. Laugier, « Phase and group velocities of fast and slow compressional waves in trabecular bone, » J Acoust Soc Am 108(4), 1949-1952. (2000).

4. D. Lheureux, A. Saied, L. Werner, J. M. Legeais, and G. Berger, « High-frequency ultrasound characterization of microporous biointegrable polymers in cornea using acoustic parameters, » Ultrasonics 38(1-8), 391-395. (2000).

5. F. Lefebvre, M. Meunier, F. Thibault, P. Laugier, and G. Berger, « Computerized ultrasound B-scan characterization of breast nodules, » Ultrasound Med Biol 26(9), 1421-1428. (2000).

6. P. Laugier, V. Novikov, B. Elmann-Larsen, and G. Berger, « Quantitative ultrasound imaging of the calcaneus : precision and variations during a 120-Day bed rest, » Calcif Tissue Int 66(1), 16-21. (2000).

7. P. Laugier, « Osteoporosis and quantitative ultrasound assessment of bone strength, » ITBM-RBM 21, 341-350 (2000).

8. C. Chappard, E. Camus, F. Lefebvre, G. Guillot, J. Bittoun, G. Berger, and P. Laugier, « Evaluation of error bounds on calcaneal speed of sound caused by surrounding soft tissue, » J Clin Densitom 3(2), 121-131. (2000).

9. S. Chaffai, V. Roberjot, F. Peyrin, G. Berger, and P. Laugier, « Frequency dependence of ultrasonic backscattering in cancellous bone : autocorrelation model and experimental results, » J Acoust Soc Am 108(5 Pt 1), 2403-2411. (2000).

10. S. Chaffai, F. Padilla, G. Berger, and P. Laugier, « In vitro measurement of the frequency-dependent attenuation in cancellous bone between 0.2 and 2 MHz, » J Acoust Soc Am 108(3 Pt 1), 1281-1289. (2000).

11. E. Camus, M. Talmant, G. Berger, and P. Laugier, « Analysis of the axial transmission technique for the assessment of skeletal status, » J Acoust Soc Am 108(6), 3058-3065. (2000).

1999

1. C. Roux and P. Laugier, « Evaluation de l’ostéoporose post-ménopausique par ultrasons, » J Radiol 80, 279-284 (1999).

2. P. Laugier and C. Roux, « Utilisation des ultrasons dans le dépistage de l’ostéoporose, » La Revue du Praticien Gynécologie Obstétrique 36, 15-21 (1999).

3. P. Laugier, « The basic physics of ultrasound, » in In Quantitative ultrasound : Assessment of osteoporosis and bone status, C. Njeh, D. Hans, T. Fuerst, C.-C. Glüer, and H. Genant, eds. (Martin Dunitz, London, 1999), pp. 47-66.

4. C.-C. Glüer, P. Laugier, and C. M. Langton, « Quantitative ultrasound : research perspectives, » in In Quantitative ultrasound : Assessment of osteoporosis and bone status, C. Njeh, D. Hans, T. Fuerst, C.-C. Glüer, and H. Genant, eds. (Martin Dunitz, London, 1999), pp. 391-411.

5. C. Chappard, G. Berger, C. Roux, and P. Laugier, « Ultrasound measurement on the calcaneus : influence of immersion time and rotation of the foot, » Osteoporos Int 9(4), 318-326. (1999).

1998

1. C. Roux and P. Laugier, « Evaluation de l’ostéoporose par ultrasons, » La Presse Médicale 27(32), 1652-1657 (1998).

2. F. Lefebvre, G. Berger, and P. Laugier, « Automatic detection of the boundary of the calcaneus from ultrasound parametric images using an active contour model ; clinical assessment, » IEEE Trans Med Imaging 17(1), 45-52. (1998).

3. P. Laugier, E. Laplace, J. L. Lefaix, and G. Berger, « In vivo results with a new device for ultrasonic monitoring of pig skin cryosurgery : the echographic cryoprobe, » J Invest Dermatol 111(2), 314-319. (1998).

4. P. Laugier, G. Berger, and M. C. De Vernejoul, « Remodelage osseux et minéralisation, » La Revue du Praticien Gynécologie Obstétrique 48, 1185-1190 (1998).

5. E. Cherin, A. Saied, P. Laugier, P. Netter, and G. Berger, « Evaluation of acoustical parameter sensitivity to age-related and osteoarthritic changes in articular cartilage using 50-MHz ultrasound, » Ultrasound Med Biol 24(3), 341-354. (1998).

6. L. Bridal, A. Saïed, E. Chérin, F. Lefebvre, P. Laugier, and G. Berger, « High-resolution quantitative echography with tissue parameters, » JEMU 19, 204-211 (1998).

Dans la même rubrique :