Partenaires

Logo tutelle
CNRS



Rechercher

Sur ce site

Sur le Web du CNRS


Accueil du site > Productions scientifiques > Articles > Publications en 2004

Publications en 2004

Abel S, Sterpone F, Bandyopadhyay S, Marchi M. Molecular modeling and simulations of AOT-water reverse micelles in isooctane:structural and dynamic properties. J Phys Chem B 2004 ;108:19458-19466.

Albrecht T, Blomley M, Bolondi L, Claudon M, Correas JM, Cosgrove D, Greiner L, Jager K, Jong ND, Leen E, Lencioni R, Lindsell D, Martegani A, Solbiati L, Thorelius L, Tranquart F, Weskott HP, Whittingham T 2004 Guidelines for the use of contrast agents in ultrasound. January 2004. Ultraschall Med 25(4):249-56.

Bossy E, Talmant M, Peyrin F, Akrout L, Cloetens P, Laugier P. An in vitro study of the ultrasonic axial transmission technique at the radius : 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity. J Bone Miner Res 2004 ;19(9):1548-56. Epub 2004 Jun 02.

Bossy E, Talmant M, Laugier P. Three-dimensional simulations of ultrasonic axial transmission velocity measurement on cortical bone models. J Acoust Soc Am 2004 ;115(5 Pt 1):2314-24. (full text pdf)

Bossy E, Talmant M, Defontaine M, Patat F, Laugier P. Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone : a validation on test materials. IEEE Trans Ultrason Ferroelectr Freq Control 2004 ;51(1):71-9.

Bridal SL, Jouannot E, Jolly C, Saied A, Correas J-M, Laugier P. Ultrasonographie de haute fréquence du petit animal. In : Faupel M, Smigielski P, Grzymala R, editors. Imagerie et photonique pour les sciences du vivant et la médecine. Lausanne Switzerland : FontisMedia SA ; 2004. p. 257-273.

Defontaine M, Bonneau S, Padilla F, Gomez MA, Nasser Eddin M, Laugier P, Patat F. 2D arrays device for calcaneus bone transmission : an alternative technological solution using crossed beam forming. Ultrasonics 2004 ;42(1-9):745-52. (full text pdf)

Haider L, Gindre M, Leguillou-Buffelo D, Laugier P, Perrot H, Carreiras F, Darbeida H. Cell attachment and spreading processes monitored by the thickness shear mode quartz sensor. IEEE Sensors J 2004 ;4(5):535-542. (full text pdf)

Laugier P, Lefebvre F, Chappard C, Roux C. Segmentation of quantitative ultrasonographic images of the calcaneus using elastic deformation of the flexible Fourier contour. J Ultrasound Med 2004 ;23(5):693-9.

Laugier P, Bossy E, Jenson F, Padilla F, Talmant M, In . Eds. , , pp. , . Évaluation la Résistance Osseuse in Vivo par ultrasons. In : M. Faupel PS, R Grzymala, editor. Imagerie et photonique pour les sciences du vivant et la médecine. Lausanne, Switzerland : FontisMedia SA ; 2004. p. 127-142.

Le Guillou-Buffello D, Helary G, Gindre M, Pavon-Djavid G, Laugier P, Migonney V. Mesure de l’inhibition de l’adhésion cellulaire sur cinq films de polymère par la technique du résonateur à quartz. ITBM-RBM 2004 ;25:34-39.

Maldonado A, Nicot C, Waks M, Ober R, Urbach W, Langevin D. Confined diffusion in a sponge phase. J Phys Chem B 2004 ;108:2893-2897.

Martinez L, Caplain E, Serfaty S, Griesmar P, Gouedard G, Gindre M. Chirp-Z analysis for sol-gel transition monitoring. Ultrasonics 2004 ;42(1-9):507-10. (full text pdf)

Padilla F, Akrout L, Kolta S, Latremouille C, Roux C, Laugier P. In vitro ultrasound measurement at the human femur. Calcif Tissue Int 2004 ;75(5):421-30. Epub 2004 Jun 17.

Pereira WC, Bridal SL, Coron A, Laugier P. Singular spectrum analysis applied to backscattered ultrasound signals from in vitro human cancellous bone specimens. IEEE Trans Ultrason Ferroelectr Freq Control 2004 ;51(3):302-12.

Saied A, Laugier P. High-resolution ultrasonography for analysis of age- and disease-related cartilage changes. Methods Mol Med 2004 ;101:249-66.

Zheng YP, Bridal SL, Shi J, Saied A, Lu MH, Jaffre B, Mak A F, Laugier P. High resolution ultrasound elastomicroscopy imaging of soft tissues : system development and feasibility. Phys Med Biol 2004 ;49(17):3925-38. (full text pdf)